站内搜索
|
详细信息 Product Name: Flowmeters with Two Vaporizer Multifunctional Anesthesia (AM-JL850) Model NO.: AM-JL850 Source: Oxygen LCD Display: With LCD Display Group: All Certification: CE, ISO13485 Kind: ICU Type: Anaesthesia Machine Display: 10.4'' / 8.4'' Trademark: AMISMED Transport Package: Carton Origin: China HS Code: 90189070 Product Description AM-JL850 Multifunctional Anesthesia machinePneumatically driven and electrically controlled systemBuilt-in ventilator, 10.4" LCD display screenClosed; Semi-Closed; Semi-Open wotking modeApplied for Adult and PediatricMain technical specifications:Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa.5-tubes Flowmeters, O2 & N2O & Air ; 0.1L/Min ~ 10L / Min;Oxygen Flush: 25~75 L / MinRespiration Mode: A/C,IPPV,SIPPV,IMV,SIMV,PCV, VCV,PEEP,SIGH,MANUALTidal Volume: Adjustable range: 50 ~ 1500 ml, Display range:0~2000mlI/E Ratio: 8:1 ~ 1:10Twovaporizers: Enflurane/ Isoflurane/Sevoflurane/HalothaneVaporizer Setting Range: 0.5%~5%Respiration Frequency : 1~100 bpm;Lung compliance: ≤30 mL / kPaIMV frequency: 1~20 bpm;PEEP: 0 ~ 2.0 kPaPtr: -1.0kPa ~ 2.0 kPaCO2 absorber capacity : 1 kgInspiratory Plateau: 0~1 S ;O2 Concentration: 21%~100%Optional: Patient monitorAlarm parameters: upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,apnea, oxygen concentration, AC power malfunction,Battery low power.AM-JL850 Multifunctional Anesthesia machinePneumatically driven and electrically controlled systemBuilt-in ventilator, 8.4" LCD display screenClosed; Semi-Closed; Semi-Open wotking modeApplied for Adult and PediatricMain technical specifications:Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa.5-tubes Flowmeters, O2 & N2O & Air ; 0.1L/Min ~ 10L / Min;Oxygen Flush: 25~75 L / MinRespiration Mode: A/C,IPPV,SIPPV,IMV,SIMV,VCV,PEEP,SIGH,MANUAL (Optional: PCV )Tidal Volume: Adjustable range: 50 ~ 1500 ml, Display range:0~2000mlI/E Ratio: 8:1 ~ 1:10Twovaporizers: Enflurane/ Isoflurane/Sevoflurane/HalothaneVaporizer Setting Range: 0.5%~5%Respiration Frequency : 1~100 bpm;Lung compliance: ≤30 mL / kPaIMV frequency: 1~20 bpm;PEEP: 0 ~ 2.0 kPaPtr: -1.0kPa ~ 2.0 kPaCO2 absorber capacity : 1 kgInspiratory Plateau: 0~1 S ;O2 Concentration: 21%~100%Optional: Patient monitorAlarm parameters: upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,apnea, oxygen concentration, AC power malfunction,Battery low power.
|